This was OCR'd from an old 1954 Ericsson catalogue, and so may contain a few typos.
GC10B, GC10B/S (CV2321)
The Dekatron counter is used for counting pulses and displaying the total. Suitable pulses may be produced from the closure of contacts, interruption of a light beam, a tachometer generator, or from a Geiger-Muller type of tube. Dekatrons present a convenient method of dividing down from one frequency to another or by registering the number of cycles of a stable frequency occurring between two events, give a measure of the time interval. These tubes have also been used to provide time marker pulses for oscillographic work.
The Dekatron Principle
Double-Pulse Dekatrons consist basically of 30 cold-cathode diodes in a common gas-filled envelope. The rod cathodes are mounted in a ring around a common anode disc. When the anode is connected through a high resistance to the positive terminal of a d.c. supply of some 400--500 V, and the cathodes are returned to the negative terminal, one of the anode-cathode gaps ionizes, and the glowing cathode is easily visible through the dome of the glass bulb. The anode current flows through the resistor, and the anode potential drops to the maintaining voltage of the glow, which is less than the voltage required to strike a further discharge, so that only one cathode glows. Suppose now a cathode adjacent to that already glowing is slowly made negative. Due to the proximity of the ionized gas, the breakdown voltage is only a few volts greater than the maintaining potential, and soon this next cathode strikes. Two adjacent cathodes are now glowing, but as there is a constant p.d. between anode and glowing cathode, the anode "follows " the negative going cathode potential. This reduces the voltage across the gap which was originally glowing until the p.d. is insufficient to maintain the discharge, and the glow extinguishes, leaving the second cathode to carry the whole anode current. Thus to cause the glow to circulate, the waveforms of the voltages applied to the cathodes must be such that each electrode is, in turn, the most negative. It has been established that the voltage required to transfer the glow to an electrode two positions removed is some five times that which is necessary for a step to an adjacent electrode, and so the direction of circulation of the glow is quite definite.
Because of this, it becomes possible to connect internally the first, fourth, seventh,
etc., cathodes into one ring, and the second, fifth, etc., into a second ring. All but one
of the remaining cathodes are commoned by a third ring, and the odd electrode has an
individual connection to a pin on the valve base.
Circuit description is facilitated by referring to the electrode series of which one
element glows when the tube is quiescent as " Cathodes," the group occupying the
next clockwise position as " First Guides," and the remaining electrodes as
" Second Guides."
Basic Method of Operation
A ten-position register is of little use by itself, but when it can be made one decade of
a multi-stage counter, the sphere of application is very wide. Such a unit, besides
displaying the count, must also produce one output signal for every ten input signals. The
simplest Dekatron drive is from a three-phase a.c. supply, with the cathodes connected to
one phase and a group of guides to each other phase, but in this case every electrode is
supplied with the input waveform, and the extraction of an output signal presents some
difficulty. The recommended drive circuits use positive guide bias so that the output
cathode can be isolated from the input pulses.
The second guides are normally positive with respect to the cathodes by a potential at
least equal to the transfer voltage. Then at the cessation of the pulse on these
electrodes, the following cathode will appear negative, and the glow will leave the second
guide. To ensure a move forward to the cathode and not backward to the first guides, these
latter are also biased positively. The effective bias is the sum of the applied potential
and that produced by the flow of anode current through the guide leaks. This latter term
is dependent on the waveform of the input pulses, and to ensure accurate counting, it is
desirable to clamp the guides to a fixed bias voltage via a diode.
The nine commoned cathodes are wired directly to earth, and the output cathode has a load
resistor in series with it so that a positive pulse is produced every time the glow
invests this electrode. When the glow current begins to flow through a load resistor, the
potential of the associated cathode rises, and tends to oppose the growth of current to
that cathode. The resultant positive potential also assists the glow to transfer from the
output cathode to one of the commoned electrodes. When the output cathode is returned to a
potential negative with respect to the commoned cathodes, the opposite effect is produced.
Hence by relating the value of the resistor to the negative voltage to which it is
returned, quite large output voltages can be produced with no sacrifice to maximum speed.
The maximum speed of the tube will, however, be reduced if the glow rests on one cathode
for more than 2,000 hours without being circulated. The recommended output circuits are
designed to obtain the maximum static life from the tube by ensuring that the glowing area
includes the adjacent guides.
Input Wave-forms
Sine waves may be applied to the tube via a simple 45" phasing network (Circuit
Section, Pig. 11) for applications such as frequency division and time pulse generation
where the input is continuous. Where it is desired to count the number of cycles in a
train of waves, the sine waves should be converted into approximately rectangular pulses
and applied to the variable duration pulse circuit (Figs. 3 and 8).
Two pulse drive circuits are recommended. Pig. 8 will handle pulses of 130-160 volts
amplitude with any duration exceeding 50 ~S providing the pulses are separated by at least
200 IIS quiescent period. The optimum conditions are 145 volts amplitude, 2:7 mark/space
ratio.
A drive circuit with a higher input impedance is shown in Fig. 10. The limits on pulse
size for this circuit are :-Amplitude 140-170 volts, duration 29-36 uS.
Pairs of negative rectangular pulses, in which the leading edge of the second pulse is
coincident with the trailing edge of the first pulse, provide another form of drive,
illustrated in Pig. 12. One pulse is applied to each of the guide rings, and a quiescent
period allows the glow to invest the cathodes. Each pulse should have a minimum duration
of 60 ciS, and the minimum separation between the trailing edge of the second pulse and
the leading edge of the first pulse of the following pair is 125 uIS. The effective pulse
amplitude, i.e., total pulse minus guide bias, should be 60 +/- 10 volts.
Inter-decade Couplings
The pulse produced at the output cathode has not sufficient power to drive the succeeding
counter directly, and either a cold cathode or thermionic valve must be used to amplify
and shape the pulse.
The GTE175M trigger tetrode has been specially designed to couple
Dekatrons, and the recommended circuit is shown in fig. 13.
Alternatively one CV858 twin triode can be used for two couplings. The circuit (pig. 14)
is similar to the one described for variable duration pulses, but has different component
values to suit the longer rise time of the input pulse. The triode is coupled to the
preceding Dekatron by a small capacitance so that the " carry " takes place as
soon as the glow of the previous counter invests its output cathode. The grid is heavily
biased to prevent the negative pulse produced when the glow moves off the output cathode
from appearing as a large positive pulse on the guides and damaging the succeeding
Dekatron.
Re-setting
To enable the counters to be set at zero, two h.t. negative lines should be provided. One,
directly earthed, receives the returns from the Dekatron output cathodes (or the potential
dividers feeding them), the cathodes of any thermionic coupling valves, and the negative
bias supply for these valves. The other line takes all the remaining returns, and is
connected to earth via a resistor which is shorted during counting.
Operation of the " zero key " removes the short, and the current from the
counters and bleeders flows through the unshorted resistor. This raises the potential of
all Dekatron electrodes except the output cathodes, and causes the counters to reset. The
value of the reset resistor depends on the number of decades and the couplings used, and
should be chosen to produce a p.d. of 100 volts.
GC10/4B, GC12/4B
It was explained in the description of Counter Tubes that the First and Second Guides
were thus designated because negative pulses applied in that order would cause clockwise
rotation of the glow. If the pulses be applied in the reverse order, the circulation is
anti-clockwise, so allowing addition and subtraction. For muIti-decade subtraction, the
negative "carry" must take place on "9" and direction sensing circuits
usually require at least one intermediate output. The computing tubes therefore, besides
being tested in both directions, have four individual cathodes, A, B, C and D, brought out
to pins on the valve base, the remaining cathodes being internally connected to a common
ring which should be wired to earth. The spacing of the output cathodes is so arranged
that, by making the appropriate cathode act as zero, an output pulse can be obtained at
any intermediate count. The method of connection is shown in the table on the relevant
data sheet.
One method of obtaining reversible coupling into the succeeding decade is described in
Ref. 4, page 45. Another method is to provide two standard coupling circuits with the
first guide output on one cross-connected to the second guide output of the other through
two rectifiers wired back-to-back, the guide being taken to the junction of the
rectifiers. The other guide is connected to two more rectifiers similarly connected to the
remaining guide feed points.
GS10C, GS12C
Dekatron selectors have found many uses in frequency dividers, batching counters,
generators of " staircase " waveforms, and in marking one selected lead from a
group.
Selectors differ from Counters only in that each cathode has its individual connection to
the valve base. Cathodes which are not required to produce an output pulse should be wired
directly to earth, the output cathodes obtaining their earth return through the load
resistor. Because the number of commoned cathodes will be only a fraction of the total,
there is no advantage in taking the cathode loads to a negative voltage, as is suggested
for counter tubes. Instead, the positive guide bias should be increased so that in the
quiescent state, the guides are always at a higher potential than a glowing cathode. To
keep the effective pulse at the recommended value, the peak amplitude of the driving
waveforms must be increased by a similar amount. With these circuit alterations, a 45 volt
output pulse can be produced at the rated counting speed.
If desired, one output resistor can be common to several cathodes, and this connection is
often used to obtain division ratios which are some fraction of the total number of
cathodes.
If a particular cathode be made very negative (of the order of 140 volts) to all the
others, the glow will move directly to it. When the chosen cathode is used as
"0" in a multi-decade counter, it is necessary to block the coupling circuit to
prevent a carry pulse being produced. An alternative method of setting is described in
reference 6, page 45.
GC10-D
Unlike other Dekatrons, these tubes require only a single pulse for each count. They
are similar in appearance to doublepulse counters, but have three guide electrodes instead
of two between successive cathodes.
The negative input pulses are applied via a high resistance to the first guides and
directly to the second guides. These two groups of guides are normally biased positively
with respect to the earthed cathodes. The cathodes are preceded by the third guides, which
are connected to earth through a high resistance. The receipt of an input pulse transfers
the glow from a cathode to a first guide, and the anode current by flowing through the
first guide resistor, raises the voltage of the guide. When the potential difference
between first and second guides is equal to the transfer voltage, the glow moves
(auto-transfers) to the second guide, where it rests until the pulse voltage is removed.
The return of the first and second guides to the positive bias potential moves the glow to
the third guide, and again an auto-transfer takes place to the cathode, so completing one
count. The rate of change of voltage on the guides is kept to a suitable figure by small
capacitors in parallel with the auto-transfer resistors.
It is not anticipated that the GC1OB with its wide tolerances in operating conditions,
will be replaced by the GC1OD for low speed applications. Hence, the recommended output
circuit (Fig. 7, page 52) is a pulse-shaping amplifier which increases the amplitude and
duration of the GC1OD output pulse sufficiently to operate a GC1OB.
If the output cathode be made some 140 volts negative with respect to the commoned
cathodes, the glow will jump directly to it. In a multi-decade counter it is necessary to
block the coupling circuits during re-setting to prevent "carries:' being produced.
GR10A
In order to count pulses at rates greater than 20 kp/S, it is essential to precede the
Dekatron scaler with hard valve decades. To preserve uniformity of display, the register
tube has been introduced. Like a Dekatron it has a common anode and ten cathodes, but
there are no guides. The difference between striking and extinction voltage of the gaps is
of the order of 25 V which can be readily obtained from a coincidence matrix fed by the
binary decade. Thus it is possible to have a uniform presentation even though the scaler
may contain both Dekatrons and hard valve decades.
A conventional binary scale of sixteen modified by feedback into a scale of ten has eight
anodes each with two stable potentials. It is possible to select ten combinations of at
most four anodes which are all in the low potential state at one count only. These are
connected via isolating resistors to one cathode of the register tube the anode of which
is connected to some higher voltage.
The register tube cathode is required to glow when all its four associated anodes are low,
and must not glow when three are low and one is high. Thus the amplitude of the binary
anode swings must be at least four times the difference between the striking and
extinguishing voltages of the cold cathode diodes forming the register tube. The
recommended circuit and base connections have been designed to allow the maximum tolerance
in operating conditions, and to this end some cathodes are connected to more scaler anodes
than is needed to satisfy the normal glow conditions.
The de-ionization time of the gas limits the rate at which the circulation of the glow
will follow the counter. At speeds greater than some 50 kp/S the discharge will completely
extinguish, but when the pulse rate drops to a lower value, the tube will strike again and
display the correct count.
1. How to Design VR Tube Circuits, Raymond C. Miles. Electronics, October 1952.
2. An Electronic Digital Computer R. C. M. Barnes and others. August 1951.
3. The Single-pulse Dekatron, J. R. Acton. Electronic Engineering, February 1952.
4. New trigger Circuits for use with Cold Cathode Counting Tubes J. L. W. Churchill.
J.Brit.l.R.E., September 1952.
5. A Dekatron C.R.O. Time Marker J. H. L. McAuslan. Electronic Engineering, December 1952.
6. An Electronic Batching Counter R. T. Craxton. Electronic Engineering, October 1953
7. Measurement of the Size-Distribution of Spray Particles L. K. Wheeler and E. S.
Trickett. Electronic Engineering, October1953.
8. Polycathode Counter Tube Applications J. H. L. McAuslan and K. J. Brimley. Electronics,
November 1953.
9. Selective Calling for Radio-Telephone Systems J. R. Pollard. Electronic Engineering,
December 1953.
10. A High-speed Precision Tachometer W. R. Bland and B. J. Cooper. Electronic
Engineering, January 1954.
11. Cold-Cathode Counting Tubes in Cascade D. T. Whelan. Electronic Engineering, March
1954.
12. A Cold-Cathode Batching-Counter P. E. Tooke. Electronic Engineering, April 1954.